# robot code this is the subdirectory for all code that runs on the 3pi robot ## make the makefile in this directory works the same as a regular makefile, with the exception of the `make flash` command. to upload the compiled robot executable, you need to change the com port specified in the makefile in this directory (line that says `PORT ?= /dev/ttyACMx`). for windows this should be changed to `PORT ?= COMx`, where x is the number of the 'programming' com port on the programmer. this will probably change every time you re-plug the programmer, so you should try every com port until it uploads successfully. you can find available com ports in device manager on windows, or by running `ls /dev/ttyACM*` on linux. once the com port is configured, run `make flash` to upload the executable and automatically reboot the robot. another fun option in the makefile is the SIM mode. by uncommenting the line `# SIM = true`, the robot code can be compiled for desktop debugging instead. all used pololu functions must be manually implemented in sim.c for this to work, but it allows easier debugging. *it's important that the `orangutan_shim.h` header is used instead of including `` directly for this to keep working!* ## module hierarchy the software is divided into seperate 'modules' for organizational, maintenance, testing and debugging purposes. the sizes of the blocks in the following diagram are a bit misleading, as some of these blocks are mostly organizational and form more of a software 'skeleton', while the 'maze' and 'warehouse' modules provide the majority of the actual control logic. ``` ┌──────────────────────────────────────────────────────────────────────┐ │ "Hypervisor" │ └────────┬──────────────────┬──────────────────┬────────────────┬──────┘ ┌────────┴───────┐┌─────────┴────────┐┌────────┴─────────┐┌─────┴──────┐ │ Error handling ││ I/O Read & Write ││ PC communication ││ Mode logic │ └────────────────┘└──────────────────┘└──────────────────┘└─────┬──────┘ ┌──────────┬──────────────┬───────────────┤ ┌───┴──┐┌──────┴────┐┌────────┴───────┐┌──────┴──────┐ *modes* -> │ Maze ││ Warehouse ││ Emergency stop ││ Calibration │ └──────┘└───────────┘└────────────────┘└─────────────┘ ``` this diagram roughly describes how different parts of the robot software are called. most of these modules can talk to each other using functions exposed by the modules themselves (e.g. the maze module sending an error code to the error handling module, which then both handles the error and forwards it to pc communication for logging purposes). here's a quick run-down of all modules and what they're supposed to do: |module |internal name|author|purpose| |------------------|-------------|-|-| |hypervisor |`hypervisor `|N/a| backbone of all other modules; stores global variables; controls when other modules run| |pc communication |`sercomm `|Fiona| reads and parses incoming serial data; sends all data in the message buffer| |error handling |`errcatch `|Loek| receives error codes; controls how errors are handled| |i/o read & write |`io `|Jorn & Abdullaahi| reads all inputs to global state; writes all outputs| |mode logic |`modes `|N/a| executes the appropriate module for current mode| |maze |`mode_maze `|Jorn & Abdullaahi| controls robot during maze portion of map; hands off control to warehouse module| |warehouse |`mode_grid `|Loek| controls robot during warehouse portion of map; hands off control to maze module| |emergency stop |`mode_halt `|Fiona| stops all execution until emergency mode is reset by software or user| |line finding |`mode_calb `|Fiona| find line by turning on own axis if lost| |charge station |`mode_chrg `|TBD| go to the charging station transition in the grid, and continue until a black circle is found| |direct control |`mode_dirc `|TBD| respond to [DIRC](../protocol.md#DIRC) commands| |wet floor |`mode_spin `|TBD| spin uncontrollably (simulating wet floor??)| |sensor calibration|`mode_scal `|TBD| calibrate underside uv sensors| ## some standards this list will probably get updated from time to time: - modules shouldn't create any global state variables, they should use `static` variables instead. - modules are run cyclically, so they shouldn't take more than `W2_MAX_MODULE_CYCLE_MS` to execute (this is an arbitrary number, and may be changed). - documentation comments should follow the [javadoc-style doxygen format](https://wiki.scilab.org/Doxygen%20documentation%20Examples) and be placed in header (.h) files if possible. this only applies to public members (e.g. no local variables or module-internal code). - code style is mostly handled by `clang-format` and `clang-tidy`, but you should still follow these naming conventions (`` indicate placeholders): |symbol type|name|example| |-|-|-| |function|`w2__`|`w2_errcatch_pushcode`; `w2_sercomm_sendraw`| |variable|`g_w2_`|`g_w2_inputs`; `g_w2_current_mode`| |constant|`W2_`|`W2_MAX_MODULE_CYCLE_MS`; `W2_SERIAL_BAUD`| |struct|`w2_s_`|`w2_s_input_data`; `w2_s_output_data`| |enum|`w2_e_`|`w2_e_errorcodes`; `w2_e_serial_commands`| this again only applies to public members. local variables should still have short descriptive names, but shouldn't be prefixed with `w2_*`. - arbitrary numbers should be aliased to `#define` statements or `enum`s if part of a series. - general constants should be placed in `consts.h` - don't import `` directly, instead use `"orangutan_shim.h"` to keep code compatible with the simulator ## todo global todo: - [ ] start robot in calibration mode - [ ] assume robot starts in maze - [ ] maze-grid transition detection in seperate file (used by grid and maze mode) - [ ] calibrate (line-detecting) light sensors manually by placing the robot and pressing a button (maybe make this a seperate mode) ### hypervisor the hypervisor executes all other modules, and measures execution time. it also provides all other modules with a central place for defining global variables. ### pc communication the pc communication module sends messages in a binary format over the serial connection provided by the wixel modules. this module should also send a 'ping' command each cycle to check if the connection is still intact. the pc will also periodically send ping, and various other commands which this module will have to act on accordingly. ### error handling the error handling module (a) provides functions for other modules to report errors, and (b) handles errors accordingly. - [x] create an error `struct` that holds: - [x] error code - [x] message length - [x] message contents - [x] create a global error ring buffer with an appropriate size that holds error messages - [ ] handle errors in the error buffer, referencing the functional specification for details on what the robot should do to resolve each kind of error - [ ] forward error codes to the pc-communication module ~empty function declarations are in place for providing other modules an error reporting function.~ this module is as good as finished but full functionality is currently dependent on: - [ ] pc communication - [ ] other mode implementations ### i/o read & write the i/o module reads all inputs once and writes all outputs once. this keeps cycle time constant, and makes sure no time is wasted re-reading inputs, or writing outputs more than once. - [ ] create `struct`s for each type of input: - [ ] button - [ ] infrared light sensor - [ ] time-of-flight distance sensor - [ ] create a single `struct` that holds all input data - [ ] create a single `struct` that holds output data values for: - [ ] left motor speed - [ ] right motor speed - [ ] red led - [ ] green led extra (requires external interrupt setup): - [ ] add a `pressed` property to the button struct that turns on if the button was pressed outside the i/o module execution span - [ ] add a `press_duration` property to the button struct that measures button press duration, and that works when the button is pressed outside the i/o module execution span technically the wixel serial channel, programmer debug serial channel, lcd contents and speaker tones are also considered outputs, but these all take significant time or memory to update, so these will not be updated using the cyclic i/o module. ### modes modes is a shim module that forwards execution to the currently selected mode. the global variable `g_w2_current_mode` holds a pointer to the current mode. this makes sure only a single mode handler gets ran on every execution cycle. ### maze the maze mode controls the robot when it's in the maze, and sets execution to grid mode when it detects the maze-grid transition. the solving algorithm will constantly keep either left or right until (a) the maze-grid transition is detected, (b) the charging pad is detected, or (c) the starting point is detected. depending on which location is desired, the robot may continue to venture through the maze when it finds any of these. exact implementation details for this mode are yet to be determined. ### warehouse the warehouse mode controls the robot when it's in the warehouse, and sets execution to maze mode when it detects the maze-grid transition. exact implementation details for this mode are yet to be determined. ### emergency stop the emergency stop mode stops the robot from doing anything until the user determines it is safe to resume execution. - [ ] create a global variable that holds the previous mode - [ ] create a global variable that holds a 'safe' state (startup/default value = false) - [ ] add a condition in the supervisor that switches to the emergency mode if the 'safe' state variable is false - [ ] add a condition in the emergency mode handler that switches to the previous mode if the 'safe' state returns to false ### calibration the calibration sequence is used during the maze mode for re-finding the line when the robot gets lost. the robot will first try to find the line by itself when it gets lost. when it does this it will send a warning to the error buffer. in case it can't find the line anymore, it will go into emergency mode and send a critical warning. - [ ] implement line-finding sequence - turn 360 degrees (about robot's own axis) - if a line is found at any point during this rotation, stop turning - if a full rotation is completed without a found line, enter emergency mode - [ ] add a warning for line lost